COPPER-TITE 9” Retro Drains w/ 18” Flange, 10” Clamping Ring & Tape Seal
COPPER for reliable longevity, TITE for a secure water tight fit. The Copper Tite retrofit roof drain is made up of a copper body, ABS clamping ring, strainer dome and expanding tape seal to prevent water backflow.
- Quick and easy to install w/ Copper flange, New clamping ring style for single-ply roof systems
- All Copper Tite Drains Standard Length = 9 inches
- Drains come with standard 10” plastice strainer, alternate options available
MARATHON COPPER-TITE retrofit roof drains feature a 2" (51mm) wide band of high density expanding foam tape impregnated with asphalt which is factory applied in a compressed state around the drain outlet. COPPER-TITE sealant tape is designed to expand to approximately four times its compressed thickness.
COPPERTITE X 9” ‐ 18” FLANGE, W/ 10” CLAMPING RING & TAPE: FOR RE-ROOFING INSTALLATIONS | FITS INSIDE EXISTING DRAIN (SIZES 2" TO 10") | CREATES SEAL FOR WATER BACK-UP PROTECTION
- A retro-fit insert copper drain
- Seals securely within existing pipe
- Prevents water back-up problems by sealing side wall gaps with expandable waterproof tape
- Simple and quick to install, just peel off tape
- COPPER for reliable long life
- TITE for secure waterproof fit
- Expanding tape to prevent water backflow issues
- Bolt in place polyethylene strainer
- Fits drains 2" (51mm) to 10" (203mm)
- PVC or TPO coatings available for direct hot air welding
BODY: | FLANGE: | OUTLET LENGTH: | CLAMPING RING: | STRAINER: |
---|---|---|---|---|
Copper |
18" |
9" |
10" ABS |
10" Polyethylene |
PRODUCT SPECIFICATIONS & DETAILS:
PART # | FITS PIPE SIZES | DESCRIPTION | FLANGE DIAMETER |
---|---|---|---|
BCTS29CR |
1 3/4 ‐2 1/4 |
2" COPPERTITE X 9 CR (LF) |
18" |
BCTS39CR |
2 7/8 ‐ 3 1/4 |
3" COPPERTITE X 9 CR (LF) |
18" |
BCTS49CR |
3 7/8 ‐ 4 1/4 |
4" COPPERTITE X 9 CR (LF) |
18" |
BCTS59CR |
4 7/8 ‐ 5 1/4 |
5" COPPERTITE X 9 CR (LF) |
18" |
BCTS69CR |
5 7/8 ‐ 6 1/4 |
6" COPPERTITE X 9 CR (LF) |
18" |
- OPTIONS & SPECS FOR STRAINER DOMES: Plastic is standard, Aluminum & Cast Iron is optional.
- FLANGE OPTIONS: Plain finish -N/C or PVC & TPO coatings
- ALL DRAINS SUPPLIED WITH STANDARD 10” PLASTIC STRAINER
SKU | MAR-BCTS-9CR |
---|---|
Manufacturer Part Number | BCTS29CR |
Weight | 6lb |
MARATHON COPPER-TITE Drains are an economical answer to potential water back-up problems. They are designed to fit neatly into old existing drains in a retro-fit application.
COPPERTITE X 9” ‐ 18” FLANGE, WITH 10” CLAMPING RING & TAPE
ALL COPPERTITE DRAINS STANDARD LENGTH IS 9” LONGER LENGTHS AVAILABLE ‐ ALL DRAINS SUPPLIED WITH 10” PLASTIC STRAINER
3 EASY STEPS TO INSTALL:
STEP 1 Inspect the old drain for possible cracks and for a smooth clean surface. Scrape away old asphalt and dirt. Use a heat gun to soften old asphalt and to achieve a relatively dry surface, if necessary.
STEP 2 Test the size of the new COPPER-TITE drain by inserting it into the now clean original drain before removing the compression tape. With the correct size of COPPER-TITE now confirmed, remove the drain, release the compression tape and promptly re-insert the COPPER-TITE drain. The tape gradually expands to fill the space surrounding the outlet of the new COPPER-TITE there-by creating the back-up seal feature.
STEP 3 Flash in the drain flange according to methods determined by the membrane manufacturer and/or the roofer using the clamping ring, if applicable. Attach the strainer dome.
OPTIONS & SPECIFICATIONS STRAINER DOMES: Plastic is standard, Aluminum & Cast Iron is optional. FLANGE OPTIONS: Plain finish -N/C • PVC & TPO coatings
SPECIFICATIONS:
Roof Drain Pipe Size | Part # | Specification | Flange Size |
Part # |
Specification | Flange Size | Part # | Specification | Flange Size |
2" | CST29 | 175 x 9 (SF) | 14" | CTS29CR | 175 x 9CR (LF) | 18" | CTS29CR(E) | 175 x 9CR (SF) | 14" |
3" | CTS39 | 275 x 9 (SF) | 14" | CTS39CR | 275 x 9CR (LF) | 18" | CTS39CR(E) | 275 x 9CR (SF) | 14" |
4" | CTS49 | 375 x 9 (SF) | 14" | CTS49CR | 375 x 9CR (LF) | 18" | CTS49CR(E) | 375 x 9CR (SF) | 14" |
5" | CTS59 | 475 x 9 (LF) | 18" | CTS59CR | 475 x 9CR (LF) | 18" | |||
6" | CTS69 | 575 x 9 (LF) | 18" | CTS69CR | 475 x 9CR (LF) | 18" | |||
8" | CTS89 | 775 x 9 (LF) | 18" | CTS89CR | 775 x 9CR (LF) | 18" |
(SF) Small Flange
(LF) Large Flange
INSTALLATION INSTRUCTIONS FOR MARATHON COPPERTITE RETRO DRAINS: Just prior to inserting the COPPER-TITE drain the installer removes the exterior restraining tape and immediately sets the retro drain in place. The released tape gradually expands to fill the space between the COPPER-TITE drain and the existing drain sleeve making the connection watertight. COPPER-TITE sealant tape expands more slowly in cold temperatures. When heat is applied to the inside of the outlet the sealant tape expands more rapidly. Should the tape expand too much before inserting the COPPER-TITE drain, simply re-compress the tape by hand and then insert the drain.